GLASSMANN Industrial Partner

EH50P2 - Glassmann EH50P2 EH Series 100 Watt Regulated High Voltage DC...

larger image

Request Quote
For Price
Part Number:
EH50P2
Model Number:
EH50P2
Make:
GLASSMAN HIGH VOLTAGE
Lead Time:
Available
Qty In Stock:
Available

Glassmann EH50P2 EH Series 100 Watt Regulated High Voltage DC Power Supply Simple Type: Power Supply

The EH Series was designed for the user who requires premium performance coupled with “application flexible” features. The result…high voltage power supplies of superior quality…at an affordable price. Replete with standard features, there are no hidden extras.

Download the datasheet (PDF)

For Resellers and High Volume Orders:
Please request a quote to obtain preferred pricing.

Features

  • Air Insulated. As in all standard Glassman power supplies these units employ "air" as the dielectric medium. No oil or encapsulation to impede serviceability or increase weight.
  • Constant Voltage Constant Current Operation. Automatic crossover from voltage or current regulated mode dependent on the load conditions.
  • Fast Transient Response. Less than 3 milliseconds for a 50% load transient.
  • Front Panel Elements Include: Ten turn voltage and current controls with locking vernier dials, accurate 2 1/2" analog displays both voltage and current, illuminated AC power on/off switch.
  • Low Ripple. Better than 0.03% at full load.
  • Low Stored Energy. Less than 800 millijoules for most models.
  • Remote Control Facilities Include: Output voltage and current program/monitor terminals, high voltage enable/disable, safety interlock terminals, and + 10 volt reference source.
  • Tight Regulation. Voltage regulation better than 0.005% line and load; current regulation better than 0.05% from short circuit to rated voltage.
  • Unique "True Load Monitor" enables the load current to be monitored accurately with respect to ground. This eliminates the need to break the common/ground connection, and/or to program the output with
  • Warranty. Standard power supplies are warranted for three years; OEM and modified power supplies are warranted for one year. A formal warranty statement is available

Specifications

    General
  • Accessories: Detachable 8 foot shielded high voltage coaxial cable (see Models chart for cable type) and 6 foot detachable line cord are provided.
  • Ambient Temperature: -20 to +60 degrees C, operating; -40 to +85 degrees C, storage.
  • Current Monitor: Zero to +10V DC signal is equivalent to zero to rated current. Accuracy, 1% of reading +0.05% of rated current (Reversible models 1% of reading +0.1% of rated).
  • Current Regulation: Better than 0.05% from short circuit to rated voltage at any set current condition.
  • Efficiency: Better than 75% at full load. Better than 75% at full load.
  • External Interlock: Open off, close on.
  • HV Enable/Disable: 0-1.5V off, 2.5-15V on.
  • Input: 105-125V RMS 48-63Hz, single phase, less than 1.5 amperes. Input connector per IEC 320 with mating line cord provided. 105-125V RMS 48-63Hz, single phase, less than 1.5 amperes. Input connector per IEC 320 with mating line cord provided.
  • Output: Continuous, stable adjustment, from 0 to rated voltage or current by panel mounted 10-turn potentiometers with 0.05% resolution, or by external 0 to 10V signals is provided. Linearity is <1% of rated. Accuracy is 1% of rated + 1% of setting. Repeatability is <0.1% of rated. Continuous, stable adjustment, from 0 to rated voltage or current by panel mounted 10-turn potentiometers with 0.05% resolution, or by external 0 to 10V signals is provided. Linearity is <1% of rated. Accuracy is 1% of rated + 1% of setting. Repeatability is <0.1% of rated.
  • Polarity: Available with either positive, negative, or reversible polarity with respect to chassis ground.
  • Protection: Automatic current regulation protects the power supply against all overload conditions, including arcs and short circuits. Fuses, surge limiting resistors, and low energy components provide the ultimate protection.
  • Remote Controls: Common, +10 volt reference, interlock, current monitor, current program, voltage monitor, voltage program, HV enable/disable, and ground provided on a rear panel terminal block.
  • Ripple: Better than 0.03% RMS of rated voltage +0.5V at full load. Better than 0.03% RMS of rated voltage +0.5V at full load.
  • Stability: 0.01% per hour, after 1/2 hour warm-up, 0.05% per 8 hours.
  • Stored Energy: 10kV model, 200 millijoules; 50kV model, 1 joule. 10kV model, 200 millijoules; 50kV model, 1 joule.
  • Temperature Coefficient: 0.01% per degree C.
  • Voltage Monitor: Zero to +10V DC signal is equivalent to zero to rated voltage. Accuracy, 1% of rated voltage.
  • Voltage Regulation: Better than 0.005% +1mV/mA, line and load. Better than 0.005% +1mV/mA, line and load.
  • Voltage Rise/Decay Time Constant: Using either the HV (on/off) or remote voltage control, with a 75% resistive load, the output voltage will rise or decay with a typical time constant of 60 milliseconds (100mS maximum).

 

Applications

  • None Available

Aliases

  • None Available